Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Imaging Science in Dentistry ; : 255-260, 2020.
Artículo | WPRIM | ID: wpr-835432

RESUMEN

Acquired facial lipoatrophy is a rare disease with an unclear etiology and pathological pathway. The distinct causative factors of this disease have been not elucidated, but it is suspected to be associated with immune systemrelated diseases, most notably AIDS. Although the management of facial lipoatrophy is very important for patients’ social life and mental health, no treatment framework has been developed due to the unknown nature of the disease manifestation. The present case report was designed to provide sequential imaging to visualize the disease progression. The clinical backgrounds of the patients are also introduced, helping characterize this disease entity more clearly for maxillofacial specialists.

2.
Imaging Science in Dentistry ; : 273-279, 2020.
Artículo en Inglés | WPRIM | ID: wpr-937630

RESUMEN

This review presents an overview of some diagnostic imaging-related issues regarding medication-related osteonecrosis of the jaws (MRONJ), including imaging signs that can predict MRONJ in patients taking antiresorptive drugs, the early imaging features of MRONJ, the relationship between the presence or absence of bone exposure and imaging features, and differences in imaging features by stage, between advanced MRONJ and conventional osteomyelitis, between oncologic and osteoporotic patients with MRONJ, and depending on the type of medication, method of administration, and duration of medication. The early diagnosis of MRONJ can be made by the presence of subtle imaging changes such as thickening of the lamina dura or cortical bone, not by the presence of bone exposure. Most of the imaging features are relatively non-specific, and each patient’s clinical findings and history should be referenced. Oral and maxillofacial radiologists and dentists should closely monitor plain radiographs of patients taking antiresorptive/antiangiogenic drugs.

3.
Imaging Science in Dentistry ; : 177-177, 2019.
Artículo en Inglés | WPRIM | ID: wpr-763987

RESUMEN

The authors would like to correct an error in the publication of the original article. The number in the formula on page 256, right column, line 5 should be ‘346.0121’ instead of ‘3446.0121.’

4.
Imaging Science in Dentistry ; : 273-279, 2019.
Artículo en Inglés | WPRIM | ID: wpr-785814

RESUMEN

PURPOSE: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT) (Siemens Healthineers, Erlangen, Germany).MATERIALS AND METHODS: A bone density calibration phantom with 3 HA inserts of different densities (CTWATER®; 0, 100, and 200 mg of HA/cm³) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time.RESULTS: Hydroxyapatite density was strongly correlated with HU values (correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels (correlation coefficient= −0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU (P>0.05).CONCLUSION: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.


Asunto(s)
Densidad Ósea , Calibración , Durapatita , Cabeza , Procesamiento de Imagen Asistido por Computador
5.
Imaging Science in Dentistry ; : 287-294, 2019.
Artículo en Inglés | WPRIM | ID: wpr-785812

RESUMEN

PURPOSE: This study was performed to analyze the clinical and imaging features of contemporary osteomyelitis (OM) and to investigate differences in these features on panoramic radiography according to patients' history of use of medication affecting bone metabolism.MATERIALS AND METHODS: The records of 364 patients (241 female and 123 male, average age 66.8±14.9 years) with OM were retrospectively reviewed. Panoramic imaging features were analyzed and compared between patients with medication-related OM (m-OM) and those with conventional, medication-unrelated OM (c-OM).RESULTS: The age of onset of OM tended to be high, with the largest number of patients experiencing onset in their 70s. The 2 most frequent presumed causes were antiresorptive medication use (44.2%) and odontogenic origin (34.6%). On panoramic radiographs, a mix of osteolysis and sclerosis was the most common lesion pattern observed (68.6%). Sequestrum, extraction socket, and periosteal new bone formation were found in 143 (42.1%), 79 (23.2%), and 24 (7.1%) cases, respectively. The m-OM group exhibited sequestrum and extraction socket more frequently and displayed significantly higher mandibular cortical index values than the c-OM group.CONCLUSION: We observed some differences in imaging features as shown on panoramic radiography according to the history of antiresorptive medication use. This study may help elucidate the predictive imaging features of medication-related osteonecrosis of the jaw.


Asunto(s)
Femenino , Humanos , Masculino , Edad de Inicio , Maxilares , Metabolismo , Osteogénesis , Osteólisis , Osteomielitis , Osteonecrosis , Radiografía Panorámica , Estudios Retrospectivos , Esclerosis
6.
Imaging Science in Dentistry ; : 317-321, 2019.
Artículo en Inglés | WPRIM | ID: wpr-785808

RESUMEN

Steatocystoma multiplex is an uncommon benign skin disease, which typically manifests as numerous intradermal cysts that can be scattered anywhere on the body. Although usually asymptomatic, it can be significantly disfiguring. One type of steatocystoma multiplex is known to be associated with the autosomal dominant inheritance of a mutation in the gene coding for keratin 17 (KRT17). In such cases, it is often concurrent with other developmental abnormalities of the ectoderm-derived tissues, such as the nails, hair, and teeth. To the best of our knowledge, few cases have been reported of steatocystoma multiplex of the oral and maxillofacial region. This report describes a case of steatocystoma multiplex of both sides of the neck and multiple dental anomalies, with a focus on its clinical, radiological, and histopathological characteristics, as well as the possibility that the patient exhibited the familial type of this condition.


Asunto(s)
Humanos , Codificación Clínica , Cabello , Queratina-17 , Cuello , Enfermedades de la Piel , Esteatocistoma Múltiple , Diente , Testamentos
7.
Imaging Science in Dentistry ; : 255-259, 2018.
Artículo en Inglés | WPRIM | ID: wpr-740394

RESUMEN

PURPOSE: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. MATERIALS AND METHODS: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using MATLAB®. Image layer boundaries were obtained by applying various distortion rate thresholds. RESULTS: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. CONCLUSION: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.


Asunto(s)
Adulto , Humanos , Masculino , Arco Dental , Fantasmas de Imagen , Radiografía Panorámica , Articulación Temporomandibular
8.
Imaging Science in Dentistry ; : 97-101, 2018.
Artículo en Inglés | WPRIM | ID: wpr-740374

RESUMEN

PURPOSE: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. MATERIALS AND METHODS: Disc specimens (N=24, n=6 per group, ø7 mm×1 mm) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: Multilink (3.44–4.33) showed the highest radiopacity, followed by U-cem (1.81–2.88), Panavia F 2.0 (1.51–2.69), and Duolink (1.48–2.59). The R² values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. CONCLUSION: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.


Asunto(s)
Aluminio , Esmalte Dental , Materiales Dentales , Dentina , Modelos Lineales , Intensificación de Imagen Radiográfica , Radiografía , Semiconductores , Diente
9.
Imaging Science in Dentistry ; : 87-92, 2017.
Artículo en Inglés | WPRIM | ID: wpr-191871

RESUMEN

PURPOSE: The aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age. MATERIALS AND METHODS: Four observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40–49 years, 50–59 years, 60–69 years, 70–79 years, and 80–89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data. RESULTS: Among the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased. CONCLUSION: PMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.


Asunto(s)
Humanos , Pérdida de Hueso Alveolar , Densidad Ósea , Mandíbula , Radiografía
10.
Imaging Science in Dentistry ; : 123-127, 2017.
Artículo en Inglés | WPRIM | ID: wpr-191866

RESUMEN

PURPOSE: Obstructive and inflammatory disease often occurs in the major salivary glands, and no predictive treatment has yet been developed for this condition. The aim of this report was to introduce an intraductal irrigation procedure and to illustrate its application to practical patient cases. MATERIALS AND METHODS: Two patients complaining of pain and swelling in the parotid gland during meals who underwent sialography were diagnosed as having sialodochitis with sialadenitis. Intraductal irrigation was then performed on the parotid gland on the side of the complaint. The irrigation procedure was conducted in the same manner as the sialography procedure, except that saline was used as the filling solution. Symptom severity was evaluated with a numerical rating scale (NRS) at the initial visit and a month after the irrigation. RESULTS: The initial NRS value of patient 1 was 10. The value decreased to 6 and then to 0 after 2 irrigation procedures. The NRS value of patient 2 regarding the symptoms involving the left parotid gland decreased from 4-5 to 1 after 4 irrigation procedures performed at 1-month intervals. CONCLUSION: Intraductal irrigation of the salivary gland may be a simple, safe, and effective treatment option for patients with obstructive and inflammatory disease of the salivary gland that is capable of resolving their symptoms.


Asunto(s)
Humanos , Comidas , Glándula Parótida , Glándulas Salivales , Sialadenitis , Sialografía , Irrigación Terapéutica
11.
Imaging Science in Dentistry ; : 51-55, 2017.
Artículo en Inglés | WPRIM | ID: wpr-147785

RESUMEN

PURPOSE: This study was conducted to suggest the development of a learning management system for dental radiology education using the Modular Object-Oriented Dynamic Learning Environment (Moodle). MATERIALS AND METHODS: Moodle is a well-known and verified open-source software-learning management system (OSS-LMS). The Moodle software was installed on a server computer and customized for dental radiology education. The system was implemented for teaching undergraduate students to diagnose dental caries in panoramic images. Questions were chosen that could assess students' diagnosis ability. Students were given several questions corre-sponding to each of 100 panoramic images. RESULTS: The installation and customization of Moodle was feasible, cost-effective, and time-saving. By having students answer questions repeatedly, it was possible to train them to examine panoramic images sequentially and thoroughly. CONCLUSION: Based on its educational efficiency and efficacy, the adaptation of an OSS-LMS in dental school may be highly recommended. The system could be extended to continuing education for dentists. Further studies on the objective evaluation of knowledge acquisition and retention are needed.


Asunto(s)
Humanos , Instrucción por Computador , Caries Dental , Odontólogos , Diagnóstico , Educación , Educación Continua , Educación en Odontología , Aprendizaje , Facultades de Odontología
12.
Imaging Science in Dentistry ; : 255-259, 2017.
Artículo en Inglés | WPRIM | ID: wpr-10866

RESUMEN

PURPOSE: Underlying bone sclerosis is frequently observed in clinical settings when oral squamous cell carcinoma (OSCC) invades the jaw bone. The aim of this study was to assess the prevalence and characteristics of underlying bone sclerosis in patients with OSCC. MATERIALS AND METHODS: We retrospectively reviewed the computed tomographic (CT) images of 131 patients who underwent mandibulectomy between January 2012 and December 2015 to treat OSCC. The presence, degree, and extent of underlying bone sclerosis were assessed on CT images and correlated with the following imaging patterns of bone invasion: cortical invasion, medullary invasion with a smooth margin, and medullary invasion with an irregular margin. The chi-square test was used to determine the relationships between the variables. RESULTS: The prevalence of underlying bone sclerosis on CT images was 70.1% (47 of 67). The prevalence was 85.7% (42 of 49) in patients with medullary invasion, but it was 27.8% (5 of 18) in patients with only cortical invasion, indicating a significant increase in the prevalence of underlying bone sclerosis in patients with medullary invasion (P < .05). Aggressive patterns of bone invasion were associated with increases in the degree and extent of the underlying bone sclerosis (P < .05). CONCLUSION: More than two-thirds of OSCC cases with bone invasion showed underlying bone sclerosis. On CT images, reactive sclerosis in the remaining margin of the alveolar bone should not be used as the primary means to differentiate periodontal inflammatory lesions from those resulting from OSCC.


Asunto(s)
Humanos , Carcinoma de Células Escamosas , Células Epiteliales , Maxilares , Mandíbula , Prevalencia , Estudios Retrospectivos , Esclerosis , Tomografía Computarizada por Rayos X
13.
Imaging Science in Dentistry ; : 103-108, 2016.
Artículo en Inglés | WPRIM | ID: wpr-207634

RESUMEN

PURPOSE: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. MATERIALS AND METHODS: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. RESULTS: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. CONCLUSION: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.


Asunto(s)
Humanos , Tomografía Computarizada de Haz Cónico , Clínicas Odontológicas , Odontólogos , Métodos , Dosis de Radiación , Monitoreo de Radiación , Radiografía , Radiografía Dental
14.
Journal of Periodontal & Implant Science ; : 116-127, 2016.
Artículo en Inglés | WPRIM | ID: wpr-84878

RESUMEN

PURPOSE: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. METHODS: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. RESULTS: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). CONCLUSIONS: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.


Asunto(s)
Huesos , Densidad Ósea , Médula Ósea , Tomografía Computarizada de Haz Cónico , Implantes Dentales , Diagnóstico , Porcinos , Microtomografía por Rayos X
15.
Imaging Science in Dentistry ; : 203-210, 2016.
Artículo en Inglés | WPRIM | ID: wpr-126683

RESUMEN

PURPOSE: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. MATERIALS AND METHODS: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. RESULTS: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. CONCLUSION: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.


Asunto(s)
Aluminio , Diente Premolar , Porcelana Dental , Diagnóstico , Incisivo , Maxilares , Diente Molar , Fantasmas de Imagen , Polimetil Metacrilato , Politetrafluoroetileno , Garantía de la Calidad de Atención de Salud , Radiografía Panorámica , Valores de Referencia , Cráneo , Articulación Temporomandibular
16.
Imaging Science in Dentistry ; : 25-31, 2016.
Artículo en Inglés | WPRIM | ID: wpr-146509

RESUMEN

PURPOSE: This study was performed to evaluate condylar surface changes and remodeling after orthognathic surgery using three-dimensional computed tomography (3D CT) imaging, including comparisons between the right and left sides and between the sexes. MATERIALS AND METHODS: Forty patients (20 males and 20 females) who underwent multi-detector CT examinations before and after surgery were selected. Three-dimensional images comprising thousands of points on the condylar surface were obtained before and after surgery. For the quantitative assessment of condylar surface changes, point-to-point (preoperative-to-postoperative) distances were calculated using D processing software. These point-to-point distances were converted to a color map. In order to evaluate the types of condylar remodeling, the condylar head was divided into six areas (anteromedial, anteromiddle, anterolateral, posteromedial, posteromiddle, and posterolateral areas) and each area was classified into three types of condylar remodeling (bone formation, no change, and bone resorption) based on the color map. Additionally, comparative analyses were performed between the right and left sides and according to sex. RESULTS: The mean of the average point-to-point distances on condylar surface was 0.11±0.03 mm. Bone resorption occurred more frequently than other types of condylar remodeling, especially in the lateral areas. However, bone formation in the anteromedial area was particularly prominent. No significant difference was found between the right and left condyles, but condylar surface changes in males were significantly larger than in females. CONCLUSION: This study revealed that condylar remodeling exhibited a tendency towards bone resorption, especially in the lateral areas. Condylar surface changes occurred, but were small.


Asunto(s)
Femenino , Humanos , Masculino , Remodelación Ósea , Resorción Ósea , Cabeza , Imagenología Tridimensional , Cóndilo Mandibular , Tomografía Computarizada Multidetector , Cirugía Ortognática , Osteogénesis
17.
Imaging Science in Dentistry ; : 7-13, 2015.
Artículo en Inglés | WPRIM | ID: wpr-221774

RESUMEN

PURPOSE: We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). MATERIALS AND METHODS: The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. RESULTS: VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). CONCLUSION: It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.


Asunto(s)
Implantes Absorbibles , Absorción , Procesamiento de Imagen Asistido por Computador , Oseointegración , Microtomografía por Rayos X
18.
Imaging Science in Dentistry ; : 117-122, 2015.
Artículo en Inglés | WPRIM | ID: wpr-82443

RESUMEN

PURPOSE: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. MATERIALS AND METHODS: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. RESULTS: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. CONCLUSION: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.


Asunto(s)
Humanos , Radiografía Panorámica , Reproducibilidad de los Resultados
19.
Imaging Science in Dentistry ; : 95-102, 2014.
Artículo en Inglés | WPRIM | ID: wpr-120545

RESUMEN

PURPOSE: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. MATERIALS AND METHODS: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. RESULTS: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. CONCLUSION: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.


Asunto(s)
Humanos , Cabeza , Radiografía Panorámica , Reproducibilidad de los Resultados
20.
Imaging Science in Dentistry ; : 301-305, 2014.
Artículo en Inglés | WPRIM | ID: wpr-52095

RESUMEN

PURPOSE: The purpose of this study was to compare the accuracy of postoperative maxillary cyst (POMC) diagnosis by panoramic radiographs versus computed tomography (CT) and by oral and maxillofacial radiologists versus non-specialists. MATERIALS AND METHODS: Sixty-five maxillary sinuses with POMCs and 63 without any lesion were assessed using panoramic radiographs and CT images by five oral and maxillofacial radiologists and five non-specialists on a five-point scale. The areas under receiver operating characteristic (ROC) curves were analyzed to determine the differences in diagnostic accuracy between the two imaging modalities and between the two groups of observers. The intra-observer agreement was determined, too. RESULTS: The diagnostic accuracy of CT images was higher than that of panoramic radiographs in both groups of observers (p<0.05). The diagnostic accuracy of oral and maxillofacial radiologists for each method was higher than that of non-specialists (p<0.05). CONCLUSION: The use of CT improves the diagnosis of POMC, and radiological training and experience leads to more accurate evaluation.


Asunto(s)
Diagnóstico , Seno Maxilar , Proopiomelanocortina , Radiografía Panorámica , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA